2.3- SINGLE PHASE CHARGING STATION AC MAINS CONNECTION
1-
Insert the cables to the terminal block as shown in the image. Check the table-6 below to match
Electric Terminal number with AC Cable Color.
2-
Tighten the screws on the terminal block as shown in the image with the tightening tourqe of
2.5Nm.
Electric Terminal
IG v7.3.0 2020
1
2
3
© 2020 Vestel - All rights reserved
1
Figure-11
Earth (Green-Yellow)
Table-5
2
1
AC Cable Color
AC L1 (Brown)
AC Neutral (Blue)
English - 21