Specification

14.3 Tests in accordance with VDE 0701/0702
Earth conductor check
f Check the earth conductor (in Germany e.g. DGUV A3) on the
earth conductor contact of the power cable and on the appli-
ance connector.
Insulation resistance
Due to the electronic control of this appliance, an insulation re-
sistance test to VDE 0701/0702 cannot be carried out.
f To check the effectiveness of the insulating properties of the
appliance, we recommend conducting a differential cur-
rent test of the earth conductor current / leakage current to
VDE 0701/0702 (Fig. C.3b).

14.4 Appliance storage

f Store the dismantled appliance free from the risk of frost, as
water residues remaining inside the appliance can freeze and
cause damage.
14.5 Replacing the power cable for the
EIL 6 Premium
f If replacing the cable for the EIL 6 Premium, use a power
cable with 4 mm² cross-section
20
| EIL Premium
15. Specification

15.1 Dimensions and connections

c01
c06
30
120
190
b02 Entry for electrical cables I
b03 Entry electrical cables II
c01
Cold water inlet
c06
DHW outlet
20
b02
b03
82
Male thread
G 3/8 A
Male thread
G 3/8 A