Operation
the On/Off switch to OFF and
waiting 5 minutes before switching
it to ON. The overheat cutout will
be triggered if the filter is dirty.
Follow filter
maintenance.
CAUTION:
continuously reset the heater,
disconnect power and contact
your dealer.
Remote Controls
An optional remote control can be
purchased to operate the fireplace
- EFRC. This will allow the user
the ability to toggle through the
stages of operation: Flames,
Flames/Fan, and Flames/Heat,
with a remote control.
Wall Mounted Controls
The fireplace can be installed
with wall mounted controls. These
controls include wall switches
and thermostats. (see individual
installation guides for details)
1. Wall Mounted Switches
This model may be installed
so that a wall mounted switch
energizes the firebox and
flame, (On/Off Switch must
be in the ON position). A
wall mounted switch may also
be used to override the flame
image, (On/Off Switch must
If you need to
be in the ON position in
coordination with any main
power wall mounted switch).
A wall mounted switch may
also be used to override the
heater option (Mode Selector
Switch must be in the "="
position).
2. Wall Mounted Thermostat
This unit may be installed
so that a wall mounted
thermostat can adjust the heat
temperature to your individual
requirements. Please refer
to thermostat manufacturers
operation Instructions.
Mode Selector Switch must
be set to "=" for thermostat
to control heater/.
7