Funciones de los componentes
En el capítulo 11.2 se pueden consultar descripciones más detalladas de los códigos de fallo, las causas y la
solución.
Condition Monitoring [CM] (0x0092)
Parameter Off-
146 (0x0092)
set
Description
Condition Monitoring of ejector #1-#16
Index
Index 0 ...15 corresponds to ejector #1...#16
Datatyp
uint8
Length
16 Byte
Access
read only
Value range
Byte 1 ...16:
Bit 0 = Valve protection active
Bit 1 = Evacuation time greater than limit
Bit 2 = Leakage rate greater than limit
Bit 3 = H1 not reached in suction cycle
Bit 4 = Free flow vacuum too high
Bit 5 = Manual Mode Active
Default value
0
Unit
-
EEPROM
no
Parameter Off-
146 (0x0092)
set
Description
CU Condition Monitoring [part of processdata] (Condition Monitoring of Con-
trol Unit)
Index
16
Datatyp
uint8
Length
1 Byte
Access
read only
Value range
Bit 0 = Primary Voltage limit
Bit 1 = Secondary voltage limit
Bit 2 = Input pressure limit (3,5 ... 5 bar)
Bit 3 = Warning in one or more ejectors
Default value
0
Unit
-
EEPROM
no
IO-Link Communication Status
Mediante este parámetro se puede determinar el estado actual de la comunicación IO-Link en el puerto
maestro de IO-Link.
Parameter Off-
32 (0x001F)
set
Description
IO-Link Communication Status
Index
Index 0 ...1 corresponds to IO-Link Master #1 ... #2
Datatyp
uint8
Length
2 Byte
Access
read only