6. MAINTENANCE
Use a soft damp cloth to clean the front panels. Do not use products containing alcohol or window cleaning
products.
7. TECHNICAL SPECIFICATIONS
Power voltage: ...............................................................................................12 V~ 24 V~ or 10.5 V
Consumption (max): .......................................................................................................250 mArms @ 12 V
Operating temperature: .............................................................................................................-10 °C + 55 °C
Door open contact:
Type of contact:...........................................................................................................................C, NC, NO
Max. switchable voltage: ....................................................................................................................... 30 V
Max. switchable current: ......................................................................................................................3,5 A
Max. load: ................................................................................................................................40 VA / 25 W
Timing: ............................................................................................................................................. 0 ÷ 99 s
Supported user key type: ..................... Dual technology key (Ref. 1125/52) or Mifare Plus (Ref. 1125/53)
Max. number of keys that can be stored .................................... 2000 (1997 user keys and 3 master keys)
Dimensions (WxHxD): .......................................................................................................... 99 x 120 x 30 mm
Wires with cross-section area of 0.5 mm
crosssection area smaller than 0.5 mm
8. KEY TO SYMBOLS
Symbol
Direct input voltage
~
Alternating input voltage
See the installation manual of the device
9. SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment types:
ILA MODULE AND PROXIMITY KEY READER FOR MIKRA with code Ref. 1784/45
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.urmet.com
DS1784-005
Key memory absent or faulty
Key memory data consistency error.
Write to memory error.
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
Description
24 V
200 mArms @ 24 V
or Mifare (Ref. 1125/54)
~
~
25