14. Troubleshooting
Fault
EN
Catalyser fan fails to run. • Mains power cord not plugged in.
Catalyser heater fails to
heat.
Excessive smoke.
Possible cause
• Control cord not connected.
• Fuse blown.
• The oven controller has not
switched the Catalyser on.
• Mains power cord not plugged in.
• Control cord not connected.
• Fuse blown.
• The oven controller has not
switched the Catalyser on.
• Catalyser cartridge exhausted.
Corrective action
• Plug the power cord in.
• Make sure the control cords is properly seated at
both the oven and the Catalyser.
• Have the fuse replaced by a qualified electrician.
• Refer to the Magma preheating oven's operating
instructions.
• Plug the power cord in.
• Make sure the control cords is properly seated at
both the oven and the Catalyser.
• Have the fuse replaced by a qualified electrician.
• Refer to the Magma preheating oven's operating
instructions.
• Replace the Catalyser cartridge (refer to Sec. 6.1).
We reserve the right to make technical changes.
- 4 -