Detection of forced entry operation
Detection of forced entry starts operating 30 seconds after the door is closed.
siren, press a button on a memorised remote control.
Adding a remote control without accessing the motor head
With a Keygo (Fig.12a)
A
A
TROUBLESHOOTING
Digital display
The LCD display is situated under the lighting cover. It provides motor operation status.
The main operating codes are as follows:
Code
Description
C1
Waiting for a command
C2
Door opening
C3
Waiting for the door to close
C4
Door closing
C5
Obstacle detection
C6
Safety input active
C9
Pedestrian door safety contact active
Cb
Permanent hardwired control
CC
Maintenance is required
Cd
Working from back-up battery
Waiting for a command
H1
Detection of forced entry
H2
Detection of forced entry
If other codes are displayed, contact your Somfy installer.
Power outage
Following a power outage, the motor must recognise its «fully open» position again.
Open the door fully using a memorised remote control. The door will open at a degraded speed.
Allow the door to open to the "fully open" position.
12a
2s
B
Comments
Indicates that the door encountered an obstacle. The display is maintained for 30 s after detection.
Indicates that an obstacle preventing door closure is present between the photoelectric cells or is in contact with
the safety sensor bar installed on the door.
Indicates that the pedestrian door within the garage door is open. Door operation is inhibited.
Indicates that the hardwired control input is permanently active. Commands from radio remote control units
are inhibited.
Indicates that maintenance is required on the installation. Contact your installer.
Indicates that the main power supply to the motor is cut and that the motoris powered by the battery back-
up pack.
Indicates that an attempt to open the garage door has been made from outside.
Press a button on the memorised remote control to stop the siren.
Start a complete opening and closing cycle.
Indicates that an attempt to open the garage door has been made from outside.
Press a button on the memorised remote control to stop the siren.
Start a complete opening and closing cycle.
With a Telis or similar (Fig.12b)
12b
A
B
2s
< 1s
5