SETUP AND OPERATING OPTIONS
General setup diagram
Meanings of the various parameters
Programming example: adjusting the long slowdown zone "P1=3" (Fig. 24)
Code
Description
Obstacle detection sensitivity
P0
Closure approach speed
P1
Memorising the remote control for partial opening cycle
Memorising the remote control for controlling lighting
Memorising a Telis or similar type remote control
SPECIAL OPERATION
Refer to the User's Manual.
CLEARING REMOTE CONTROLS AND ALL SETTINGS
Clearing remote controls
Press the "PROG" button until the light blinks (7 s).
This clears all of the remote controls memorised.
Resetting all settings
Press the "SET" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default values.
LOCKING PROGRAMMING
Used to lock the programming settings (end limit setting, self-learning, setup).
Simultaneously press the "SET", "+" and "-" buttons:
- start by pressing "SET".
- pressing "+" and "-" must take place within two seconds.
Pressing the "SET" button then no longer has any effect.
The remote control memorising functions ("PROG" button) and forced mode operation ("+", "-" buttons) remain possible.
To access programming mode once again, repeat the same procedure.
REFITTING COVERS
Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in one of the two positions shown in Figure 31.
Fig.
23
Values
1
: low sensitivity
2
: low sensitivity
3
: standard
4
: high sensitivity
1
: no slowdown
2
: short soft stop
3
: long soft stop
Fig.
28
Fig.
29
(Fig. 30)
(Fig. 31)
Comments
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure
P1=1: no slowdown before closure.
P1=2: speed is reduced during the last 20 centimetres.
P1=3: speed is reduced during the last 50 centimetres.
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure.
Fig.
25
Fig.
26
Fig.
27
7