End-of-travel stops [Fig. 5 (1)] are composed of a holder and magnet. Place the door in the open position, with the
end-of-travel assembly at the correct side, over the rack and in front of the detector [Fig 5 (2)] (max. 15 mm. min. 5
mm.) [Fig. 6]. Repeat the operation with the door closed. Adjust the installation by moving the end-of-travel
assembly one tooth ahead, or by correcting the position using the mounting hole of the assembly bracket.
.

MANUAL OPERATION

A simple manual release key makes it possible to operate the door in case of power failure or malfunction.
1With the key provided, open the lock and pull the release lever outwards.
2Turn the handle 180 degrees to unlock the drive.

DESCRIPTION OF THE TERMINALS

1. Sensor power supply, negative (Black)
2. Sensor power supply, positive (Red)
3. Sensor signal (White)
4. 0V (Earth)
5. Alternative Button (NA)
6. Safety Contact (NC)
7. 0V (Earth)
8. 0V (Earth)
9. 12V DC
10. Flashing light contact. No voltage (N.A.)
11. Flashing light contact. No voltage (N.A.)
12. Open Motor
13. Close Motor
14. Motor Earth
Note: N.O. Normally Open - N.C. Normally Closed
MICROSWITCH FUNCTIONS:
1. Automatic Closing
ON :
Timed automatic closing
OFF :
No automatic closing
2. Function Mode A / B
ON :
Operation B
OFF :
Operation A
3. Rotation Direction
ON :
Change motor and end-of-
travel direction:
OFF:
Ordinary
4. Photocell. Section 1 /Open Edge (23/24)
(Sec.1/OP Edge)
ON :
Safety edge 8,2 kOhm on opening
OFF:
Photocell on opening
5. Soft Stop Yes / No
ON :
Soft stop at the end of travel
Q
II
(Auto Closing)
(Func Mode)
(Rot. Direction)
(Soft Stop Y / N)
15. Courtesy light output 230V
16. Courtesy light output 230V
17. Power supply: 230V
18. Power supply: 230V
19. End-of-travel earth
20. End-of-travel Close (N.C.)
21. End-of-travel Open (N.C.)
22. Photocell Test
23. Contact (NC) / Safety margin opening
24. 0V (Button earth)
25. Close button (NA) or Contact (NC) /
Safety margin closing.
26. Open Button (NA)
27. Antenna
28. 0V (Earth)
6. Programming by radio
ON :
Allowed
OFF :
Not Allowed
7 Pedestrian opening push button
Opening)
ON:
The open button acts as pedestrian entrance
and only opens part of the way
OFF:
The open button fully opens the
door
8. Programming with alternative soft stop
(Prog. Soft Stop)
ON :
The slower section of travel is memorised
with the alternative
(Prog by radio)
(Pedest.
English