SUMP SYSTEM OPERATION TESTING

TESTING AUTOMATIC PUMP OPERATION

1.
The 6EC-CIA-SFS and 10EC-CIA-SFS automatic pumps are
equipped with an integral float-operated mechanical switch.
Automatic operation is achieved through the pump cord.
2. When these pumps are installed in a basin with a sealed cover,
switch operation cannot be observed. The sump cover usually
will have a spare hole that is plugged with a rubber plug. This
plug can be removed and switch operation can be observed.
3. Plug the power cord into a grounded receptacle with
voltage consistent with the pump voltage, as indicated
on the pump nameplate.
4. Be sure the gate valve in the discharge line is open.
5. Run water into the sump basin until the primary
pump is activated.
a. Do not attempt to run the pump without water; this could
result in permanent damage to the pump.
6. Confirm that primary pump and its control switch are
functioning as intended.
7.
Confirm that ON-OFF levels are within specification and
confirm that no potential obstructions exist that could
inhibit switch operation.
8. Confirm that there are no leaks in the primary pump discharge
plumbing and main home drain pipe plumbing.
a. It is normal for a stream of water to spray from the air
bleed hole in the primary pump's plumbing. Confirm that
this spray is captured within the sump basin.
9. Allow the pump to operate through several on/off cycles.
8

TESTING MANUAL PUMP OPERATION

1.
The 6EC-CIM manual pumps do not include an automatic
liquid level control. The pump cord for these pumps can be
plugged directly into a properly grounded receptacle with
voltage consistent with pump nameplate for continuous
pump operation.
s
CAUTION
!
a.
should be used only for emergency use or when a large
volume of water is to be pumped. The pump must be
continuously monitored during operation and disconnected
from power before the pump runs dry.
b. Pump must not be allowed to run dry. If pump is run dry,
it may damage pump and void the warranty.
2. For automatic operation of a manual pump, a separate float
switch or other liquid level control must be used.
s
CAUTION
!
a.
other liquid level control manufacturer's instructions
when installing. Failure to install it in compliance with
national and local electrical and plumbing codes and within
manufacturer's recommendations may result in electrical
shock or fire hazard, unsatisfactory performance, or
equipment failure.
b. After installing separate float switch or other liquid level
control, test operation following the steps shown in the
"Testing Automatic Pump Operation" section.
If the pump does not operate properly, consult the Troubleshooting
table. If the trouble still cannot be found, consult your pump dealer or
take the pump to a Little Giant authorized service center.
Do not let the unit run dry (without liquid). It is designed to be cooled
by pumping fluid. You may damage the seal and the motor may fail if
the pump is allowed to run dry.
If the unit is going to be idle for a period of time, follow the cleaning
instructions outlined in the next section. Do not let the unit freeze.
This may cause cracking or distortion that may destroy the unit.
This type of operation
Refer to float switch or