No change in measurements if connected
with drain illustrated. (K-7272)
16-13/16"
(427 mm)
36"
(914 mm)
19-1/4"
(489 mm)
2-5/8" (67 mm) 10-1/8"
Product Information
Applicable product:
Bath with airjets
Fixture*:
Bathing well:
Basin area,
49" (1245 mm) x 26-1/2" (673 mm)
bottom
Basin area, top
62-1/2" (1588 mm) x 29-1/4" (743 mm)
Weight
435 lbs (197.3 kg)
To overflow:
Water depth
19" (483 mm)
Capacity
90 gal (340.6 L)
* Approximate measurements for comparison only.
Drop-in cut-out
66-1/2" (1689 mm) x 35-1/2" (902 mm)
Blower
kW
V
motor:
300
220-240
Required Electrical Service
Dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current
Device (RCD):
Blower motor/control:
1160168-1-B
66-15/16" (1700 mm)
7"
(178 mm)
(258 mm)
1-3/16" (30 mm)
19-1/16"
(484 mm)
K-899-G
Hz
A
50/60
3
220-240 V, 15 A, 50/60 Hz
2-1/2" (64 mm)
33-1/2" (851 mm)
4"
(101 mm)
2-7/16"
(62 mm)
1-1/2"
Bath Drain
Notes
Install this product according to the installation guide. If the
blower motor and check valve are relocated, two access panels are
required. Locate one access panel at the blower motor/control
location and the other at the control box. Locate the blower motor
and check valve together.
Floor support under bath must provide for a minimum of 78
lbs/square foot (386 kg/square meter) loading.
Splitting the deck/surround is recommended if installing into a
deck.
Hot water supply should be 70% of capacity or greater.
Installations will vary.
Fixture conforms to ASME Standard A112.19.1/CSA B45.2. All
dimensions are nominal.
2
NOTE: Blower protrusion
beyond the rim.
Blower Motor/
Control Access
34" (864 mm) W x
15" (381 mm) H
22-3/4"
2-1/2"
(578 mm)
(64 mm)
26-7/8"
(683 mm)
Kohler Co.