4
IDENTIFICATION - CONNECTORS
AND CABLES
(+)
(-)
S1
Led
SIR
NA
CM
NF
Red cable
Black cable
5
IDENTIFICATION - KEYS AND JUMPERS
JZ Jumper
TEMPO DE SIRENE
Jumper
JP Jumper
AJUSTE DE
SENSIBILIDADE
Jumper
Auxiliary output "positive" for accessories.
Auxiliary output "negative" for accessories
(GND contact).
Zone 1 input for wire sensors.
12V/100mA auxiliary output that is
activated whenever the fence is turned on.
Indicates activated system.
Positive from the siren.
NA Contact (normally open) from the
auxiliary relay.
CM Contact (common) from the auxiliary
relay.
NF Contact (normally closed) from the
auxiliary relay.
Positive (+) from the battery.
Negative (-) from the batter.
Enables the wired sensor input at Zone 1.
Used for timing the siren to 15 seconds, 2
or 5 minutes.
It should be OPEN to enable the cutting
alarm and wire grounding. If this
jumper is closed the siren will not trigger in
case of a violation of the fence wires.
Configures the sensibility of high voltage
pulse returns.