INSTALLATION NOTES
- This device is not designed to be used by people (including children)
with reduced physical, sensory or mental capacities, or by people with
lack of experience and knowledge, unless they have been instructed on
the device use or are under the supervision of a person responsible for
their safety.
- We recommend that children are watched over to ensure they are not
playing with the device.
- Barbed or cutting wires should not be electrified by an electrifier.
- High voltage conductors should not be installed in the same conduits
as the power grid, communications and data cables or others.
- If the high voltage conductors and electric fence wires are installed near
power line areas, the separation distances should not be shorter than
those indicated on table BB.2 of the standard NBR IEC 60335-2-76
(table showed below).
Electric Energy line
voltage ( V )
> 1000 e < 33000
> 33000
- Each side of the electrified fences should be identified by warning signs
installed at regular spaces. These signs should be 100mm x 200mm,
have a yellow background and the following inscription on both sides:
"BEWARE: ELECTRIC FENCE".
58
_ENGLISH
< 1000
Separation Distance ( m )
3
4
8