Powerfix Profi+ PDM 250 A2 Manual Del Usuario E Información De Servicio página 59

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AC voltage
Range
2V
20V
200V
250V
Input impedance: 10MΩ
Frequency range: 40Hz to 400Hz
Overload protection: 250V AC RMS
Display: average value (RMS of the sine wave)
DC current
Range
200μA
2mA
20mA
200mA
10A
Overload protection: F1: F 250mA / 250V fuse
Maximum input current: 10A (input current > 2A for continuous measurement < 15 seconds and
interval > 15 minutes)
AC current
Range
2mA
20mA
200mA
10A
Overload protection: F1: F 250mA / 250V fuse
Maximum input current: 10A (input current > 2A for continuous measurement < 15 seconds and
interval > 15 minutes)
Frequency range: 40Hz to 400Hz
Display: average value (RMS of the sine wave)
Resolution
1mV
10mV
0.1V
1V
Resolution
0.1μA
1μA
10μA
0.1mA
10mA
F2: F 10A / 250V fuse
Resolution
1μA
10μA
0.1mA
10mA
F2: F 10A / 250V fuse
POWERFIX PDM 250 A2
Precision
± (1.0%+5)
± (1.2%+5)
Precision
± (1.0%+5)
± (1.2%+5)
± (2.0%+5)
Precision
± (1.2%+5)
± (1.5%+5)
± (3.0%+7)
English - 57

Publicidad

Tabla de contenido
loading

Tabla de contenido