Liberty Pumps Ascent II-ESW Manual De Instalación página 13

Ocultar thumbs Ver también para Ascent II-ESW:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Label
LED Color/State
ALARM
Water is not being evacuated from
Red/Blinking
holding tank.
LOW BATTERY
Battery is missing, defective, or needs to
Yellow/Steady
be replaced.
POWER
Normal operating condition.
Green/Steady
POWER
Safety switch condition (no signal from
Green/Blinking
safety switch; unit will not operate).
RISK OF ELECTRIC SHOCK
WARNING
 Accidental contact with electrically live parts, items, fluid, or
water can cause serious injury or death.
Problem
Water is entering the macerator holding tank slowly
Toilet flushes normally but
evacuates or drains from the bowl
slowly.
• Macerator sounds normal and
runs for 4 seconds, then after
some time runs for 4 seconds.
• No alarm.
Water is unable to enter the macerator holding tank
Toilet flushes normally but does not
evacuate or drain from the bowl.
• Macerator sounds normal and
runs for 4 seconds then remains
off.
• No alarm.
5755000H
Table 1. Alarm Panel Help
Condition
1. Verify unit is plugged into outlet.
2. Verify Green LED is steady, indicating normal operating condition.
3. Check discharge line for blockage.
4. If items 1-3 do not remedy the alarm condition, refer to Table 2
Replace with new battery.
1. Verify decorative covers in place.
2. Verify magnet in place on underside of decorative cover.
3. Safety switch is broken; consult factory.
Table 2. Troubleshooting Matrix
Possible Cause
The toilet or discharge extension might be
blocked.
Poor vent.
Accumulation in the strainer basket.
The toilet discharge or extension pipe may
be blocked.
Unit not vented correctly.
Copyright © Liberty Pumps, Inc. 2018 All rights reserved.
Corrective Action
Troubleshooting Matrix.
 Always disconnect pump (macerator) from power source
before handling or making any adjustments. Fatal electrical
shock could occur.
The piping must be cleaned.
Unit must be vented properly to open air to allow
water to enter the macerator tank. Confirm vent is
clear.
Do not use a quick vent.
Repetitively flush clean water and allow the
macerator to clear debris. If unit is unable to
self-clear the blockage, the access cover should
be removed for manual cleaning. See Access
Cover on page 10.
The piping must be cleaned.
Unit must be vented properly to open air to allow
water to enter the macerator tank. Confirm vent is
clear.
Do not use a quick vent.
Corrective Action
– 13 –