Symptom
Problem
Breaker trips immediately
1. Incorrect supply voltage.
upon energizing heater.
2. Overloaded circuit.
3. A short circuit exists in the supply
4. Defective circuit breaker.
Heater fan operates, but
1. Insufficient element temperature.
does not discharge warm air.
2. Incorrect supply voltage.
3. Element has failed.
Heater will not shut off.
1. Heat loss from room is greater than
2. Defective thermostat.
3. Thermostat wired incorrectly to heater.
Heater discharges smoke
1. Dust, lint or other matter has
or emits a burnt odor.
Element heats for a moment
1. Defective motor or internal connection.
without the fan turning, then
2. Fan or motor jammed.
immediately stops heating.
Heater does not run.
1. Thermostat set too low.
2. Heater has tripped the manual reset
3. Grill pressed against manual reset button,
4. Power not on at the circuit breaker.
5. Broken or poorly connected wire(s)
6. Defective thermostat.
Heater continually trips the
1. Dust, lint or other matter has
manual reset temperature
limit control.
2. Airflow is blocked.
3. Fan or motor is jammed.
4. None of the above.
Maintenance: For more effective and safer operation and to
prolong the life of the heater, read the Owner's Guide and follow
the maintenance instructions included with each heater. Failure to
properly maintain the heater will void any warranty and may
cause the heater to function improperly. Warranties are non
transferable and apply to original consumer only. Warranty terms
are set out below.
LIMITED THREE-YEAR WARRANTY: Cadet will repair or replace any
Com-Pak Max (CM) series element or motor found to be defective
or malfunctioning from first date of purchase through the third year.
THESE WARRANTIES DO NOT APPLY:
1. Damage occurs to the product through improper installation or
incorrect supply voltage;
2. Damage occurs to the product through improper maintenance,
misuse, abuse, accident, or alteration;
3. The product is serviced by anyone other than Cadet.
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault
of Cadet.
6. CADET'S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT
AS SET OUT HEREIN. CADET SHALL NOT BE LIABLE FOR
DAMAGES SUCH AS PROPERTY
CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EXPENSES
RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES
OR ANY EXPRESS OR IMPLIED WARRANTY.

Troubleshooting Chart

or heater wiring.
heater capacity.
accumulated inside heater.
temperature limit control
tripping the manual reset temperature
limit control.
to heater.
accumulated inside heater.
Warranty
DAMAGE
OR FOR
Solution
1. Verify that supply voltage matches the heater rating.
2. The total amperage of all heaters on a branch circuit must not be more than 80%
of the amperage rating of the circuit breaker and supply wire ratings. Use a lower
wattage heater, or reduce the number of heaters on the circuit.
3. Shorted supply or heater wires may be accompanied by severe sparking. Inspect
all supply and heater wiring insulation for damage. Do not reset the circuit
breaker until all electrical shorts have been repaired.
4. Replace the circuit breaker.
1. Allow a few moments for element to reach operating temperature.
2. Verify that supply voltage matches the heater rating.
3. Replace element.
1. Close doors and windows. Provide additional insulation, or install a higher wattage
heater or multiple heaters if necessary. (If your circuit is rated for more capacity.)
2. Adjust thermostat to its lowest setting. If heater continues to run (allow two
minutes for the thermostat to respond), and room temperature is greater than
50 degrees; replace the thermostat.
3. Refer to thermostat documentation and correct wiring.
1. Clean heater (see "Operation & Maintenance" section for instructions).
1. Heater or fan motor requires replacement.
2. Remove obstruction and press heater manual reset button (see "Operation &
Maintenance" section for instructions).
1. Adjust thermostat to a higher temperature until heater operates (see Problem #6
if the problem persists).
2. Press the manual reset button (see "Operation & Maintenance" section
for instructions).
3. Position grill so louvers do not press against manual reset button.
4. Turn on the correct circuit breaker in the main panel.
5. Turn off power at circuit breaker. Check supply wire continuity and proper
connection to heater wires.
6. The entire heater, or any of its components may be checked for continuity
to determine the cause of any problem. Repair or replace the heater.
1. Clean heater (see "Operation & Maintenance" section for instructions).
2. Remove obstruction. Maintain a minimum distance of 6 inches from adjacent
surfaces, 4.5 inches from the floor, and 3 feet for furniture or other objects placed
directly in front of the heater.
3. Remove obstruction, and press heater manual reset button (see "Operation &
Maintenance" section for instructions).
4. Replace heater assembly.
7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR
CADET PRODUCT, THE REPLACEMENT PARTS ARE SUBJECT
TO THE SAME WARRANTIES AS THE PRODUCT. THE
INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY
OR EXTEND THE UNDERLYING WARRANTIES. REPLACEMENT
OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT
CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may also
have other rights which vary from state to state. Cadet neither
assumes, nor authorizes anyone to assume for it, any other
obligation or liability in connection with its products other than as
set out herein.
If you believe your Cadet product is defective, please contact Cadet
Manufacturing Co. at 360-693-2505, during the warranty period, for
instructions on how to have the repair or replacement processed.
Warranty claims made after the warranty period has expired will be
denied. Products returned without authorization will be refused.
Parts and Service
Visit http://support.cadetco.com for information on where to obtain
Parts and Service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You
can reduce your carbon footprint by recycling this product
at the end of its useful life. Contact your local recycling
support center for further recycling instructions.
©2009 Cadet Manufacturing Co.
Printed in U.S.A. Rev. 6/09 #720082
5

Publicidad

Tabla de contenido
loading

Tabla de contenido