Symptom
Gurgling noise
Heater not working
Liquid found in or around unit
Room does not heat quickly
Heater will not shut off
* What to do if the solution in your Softheat Baseboard should leak out:
The solution in your Softheat Baseboard is 80% water and 20% Ethylene Glycol (Material Safety Data Sheet available upon request). While this solution is moderately toxic if
ingested, there is no immediate health concern with air quality following a spill. Take adequate precautions to keep people and animals away from leakage. Non-porous rubber
gloves and eye protection should be worn during the clean-up.
Soak up spill with an absorbent material such as paper towels. Once excess liquid or residue has been absorbed, a non-oxidizing cleanser such as an orange citrus cleaner can
be used to remove any remaining dried residue (first test a hidden section of flooring for colorfastness). Scrub spill area, then use absorbent material to remove any remaining
cleanser. Several applications of the cleanser may be required, depending on size and amount of spill.
Warranty Information
Maintenance: For safer operation and to prolong the life of the heater, it
is necessary to follow the maintenance instructions included with each
heater. Failure to properly maintain the heater will result in the warranty
being voided. All warranties offered to original consumer only. Warranty
instructions included with each heater.
LIMITED ONE-YEAR WARRANTY: Cadet Manufacturing Co. will repair
or replace any Cadet product, including thermostats, found to be
defective or malfunctioning from first date of purchase through the first
year.
LIMITED FIVE-YEAR WARRANTY: Cadet Manufacturing Co. will repair
or replace any Cadet/Softheat baseboard (E) element found to be
defective or malfunctioning from first date of purchase through the fifth
year.
Troubleshooting Chart
Problem
1. Unit may not be level
2. Unit may have developed a leak
1. Heater does not have proper voltage
to function correctly
2. Unit wired incorrectly
1. Heat transfer fluid may be escaping
from element
1. Unit is slow to heat
2. Unit wired incorrectly
1. Heat loss from room is greater than
heater capacity
2. Defective thermostat
3. Thermostat wired incorrectly to
heater
Warranty
Solution
1. Check to be sure unit is level. If gurgling doesn't stop within 30 minutes, unit
needs to be replaced.
2. Replace element or heater.
1. Circuit breaker could be positioned incorrectly. Relocate breaker. Check
voltage at the heater between supply wires and make sure it matches
required heater voltage.
2. Using Owner's Guide, verify wires are connected properly and securely with
appropriate wire nuts. If the unit is still not operating, further testing should
be done with ohmmeter. Consult an electrician.
1. Immediately discontinue use.*
2. Replace element or heater (elements are not repairable).
1. No solution necessary - typical initial warm-up takes 30-60 minutes.
2. Check voltage at the heater between supply wires and make sure it matches
required heater voltage.
1. Close doors and windows. Provide additional insulation, install a higher-wattage
heater or multiple heaters, if necessary.
2. Adjust thermostat to its lowest setting. If heater continues to run (allow two minutes
for the thermostat to respond), replace thermostat..
3. Refer to thermostat documentation and correct wiring.
These warranties do not apply:
1. To conditions resulting from improper installation or incorrect
supply voltage;
2. To conditions resulting from improper maintenance, misuse, abuse,
accident, or alteration;
3. To service calls, or any warranty labor not performed at the
Cadet Manufacturing facility;
4. If the date of manufacture cannot be determined;
5. To freight damaged products.
CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY
DAMAGE AND/OR INCIDENTAL EXPENSES RESULTING FROM
BREACH OF THESE WRITTEN WARRANTIES OR ANY IMPLIED WAR-
RANTY.
These warranties give you specific legal rights, and you may also
have other rights which vary from state to state. Cadet neither
assumes, nor authorizes anyone to assume for it, any other obligation
or liability in connection with these electric heaters or any part of
such heaters.
If the product should become defective during the warranty period,
contact Cadet Manufacturing Co. at 360-693-2505 for instructions on
how to have the repair or replacement processed. Products returned
without authorization will be refused.
Parts and Service
Contact Cadet for information on Parts or Service.
©2006 Cadet Manufacturing Co.
Printed in U.S.A. 02/06 #706955