Operation
Mounting attachment on optical sight
•
Remove the eyepiece cover (2).
•
Select the Ring Adapter (12) (sold separately) with the insert (11) of the
required diameter depending on the outer diameter of the lens of your
optical sight (10) (see Table). The designation 42 mm / 50 mm / 56 mm in the
name of the adapter means the lens diameter of the optical sight.
Selection table for optical sight inserts
The internal diameter of the insert needs to match the outer
diameter of the objective lens housing of the daylight optical
Ring
device it is being installed on.
Adapter
model
Insert internal diameter,
mm
45.5
46
PSP Ring
46.5
Adapter 42
47
mm
48
49
50
51.6
53.4
55
PSP Ring
Adapter 50
56
mm
57
58
59
60
61
PSP Ring
62
Adapter 56
63
mm
64
65
•
Screw together the Ring Adapter (12) and the attachment along the threads
of the mounting area (17) until it stops. Then untighten a little (no more than
one turn) so that the lever (16) is on the right side (see Figure).
•
Evenly tighten the screws (13) until the ball joint grips in the Ring Adapter (12).
•
Apply 2-3 strips of double-sided tape to the outer surface of the insert (11)
of your choice.
•
Push the insert (11) of your choice into the Ring Adapter (12) until it stops.
•
Move the lever (16) to the OPEN position.
•
Before installing the Ring Adapter (12) onto the optical sight, it is
recommended to degrease the lens body of the optical sight (10).
•
Mount the Ring Adapter (12) with the insert (11) onto the lens of the daylight
optical sight (10) as far as it will go.
5
ENGLISH
Suitable for lens housing of daylight
optical devices with an outer
diameter of, mm
45.5
46
46.5
46.7-47.6
47.7- 48.6
48.7-49.6
49.7-50.6
51.6
53.4
54.7-55.6
55.7-56.6
56.7-57.6
57.7-58.6
58.7-59.6
59.7-60.6
60.7-61.6
61.7-62.6
62.7-63.6
63.7-64.6
64.7-65.6
•
If the Ring Adaptor (12) with the insert (11) selected according to the table
cannot be mounted onto the lens (10), follow the steps below:
- Loosen the locking screw (14) with a 2mm Allen key.
- Untighten the screw (15) with a hex wrench (S = 4mm) until the Ring
Adaptor with the insert can be mounted onto the lens (10).
•
Move the lever (16) from its initial OPEN position to the CLOSE position.
•
Loosen the locking screw (14) with a 2mm Allen key, if it hasn't been done
before.
•
Tighten the screw (15) using a 4mm Allen key. The clamping force should be
1.5-2 Nm (use a torque screwdriver) to ensure the lever is correctly tightened
(16), while the Ring Adapter with the attachment should not move relative to
the body of the optical sight (10). If necessary, tighten or loosen the screw
(15) to operate the lever (16) in the best way possible.
•
Tighten the locking screw (14) as far as it will go.
•
Turn on the attachment by briefly pressing the ON button (6).
•
Align the display center with the crosshairs of the reticle by tilting the
attachment.
•
Align top and bottom display boundaries parallel to the horizontal axis of the
optical sight by turning the attachment clockwise or counterclockwise.
•
Having reached the best possible position of the attachment, tighten the two
screws (13) until stop. The clamping force should be 6.5-7.5 N·m (use a torque
screwdriver to check).
Crosshair
Display of attachment
10
11
Powering on and image setup
•
Remove the lens cover (1).
•
Press the ON button (6) to turn on the attachment.
•
If necessary, adjust the reticle sharpness according to the instructions for
your scope.
•
Enter the main menu with a long press of the controller button (8) and select
the desired calibration mode: manual (M), semi-automatic (SA) or automatic (A).
•
Calibrate the image by briefly pressing the ON button (6). Close the lens
cover before manual calibration.
17
12
13
15
9
Open
14
Close
16
ENGLISH
6