BSL 2470
..3.
Operation
i
If the yellow LED flashes (battery lies in un-
der-voltage range) the start-assist measu-
re may not be performed. You should first
charge the battery at least until the yellow
LED lights continuously.
7.
Start the engine
!
The start-assist measure should only be run
for a maximum of 8 seconds! After this a
cooling-down phase of approximately 7 mi-
nutes for each case should be adhered to.
8.
Switch off the battery charger after the
start-assist measure.
9.
Disconnect the crocodile clips from the
battery (remove the blue negative one
first).
Robert Bosch GmbH
3.6
Troubleshooting
Battery charger does not function after
switch on (red LED does not light):
Unplug the mains cable and check the
mains supply and the mains fuse system.
Red LED flashes after connecting the batte-
ry terminals:
Check that the battery is correctly con-
nected. The red crocodile clip must be
connected to the battery's positive termi-
nal (+) and the blue one to the negative
terminal (-).
Possible interruption to the charging process:
If the battery charger's transformer re-
aches temperatures of > 150 °C during
operation, a thermostatic switch integra-
ted into the transformer will switch off the
charging process and then switch it on
again after it has cooled down.