2 INSTALLATION MANUAL
2.1 General information
The heater must only be installed by an authorized technical installer,
in compliance with all instructions contained in this manual, the UNE
26 standard, and local regulations affecting installation and exhaust.
2.2 Location
The combustion circuit is sealed off from the installation environment, so the unit can be
installed in any room. Nonetheless, the installation site must be sufficiently ventilated to
avoid hazardous situations in the event of a gas leak.
European directive 90/396/EEC establishes this safety standard for all gas-powered
equipment, including those with a sealed chamber.
The unit can operate in a partially protected environment in accordance with standard
EN 297 pr A6.
In any case, the unit must be installed in a location free of dust, flammable objects or
materials, or corrosive gases.
The unit may be installed on a wall.
Attach it to the wall in accordance with the dimensions indicated in section 4.1. The wall
installation must be firm and stable.
If the unit is installed inside a cabinet or joined laterally to other elements,
space must be allowed for removing the casing and performing normal
maintenance activities.
A
A
fig. 7 - Minimum distances
2.3 Assembling the heater
Before assembling the heater, make sure the water and gas connections
are properly secured, identified, and positioned.
See the dimensions and connections in section 4.1.
1 - Open the packaging, and you'll find an assembly template for the unit inside. Place it
on the wall at the appropriate height (be sure to observe the distances described
in the previous section), and make sure the template is as horizontal as possible
(using a level).
2 - Mark the position of the attachment holes.
3 - With a drill and Ø8 mm bit, make the holes and insert the expansion plugs.
4 - Insert the fastenings to be used to attach the unit.
44
EN
A - On each side
> 2 cm
B
> 50 cm
C - In front > 2 cm
B
code A73022090
8
fig. 8 - Assembly template
5 - Remove the unit from the packaging.
6 - Verify all documents.
7 - Remove the plugs from the water and gas connections (see Fig. 10, p. 4).
8 - On the rating label, check the destination country reference and the type of gas for
which the unit is supplied.
fig. 9 - Rating label
SKY ECO F
8
Ø 3/4"