7. Installation
7.4. Installation Specifications
7.4.1 Installation and Floor Loading Information
Battery Cabinet Model
BP480V370
BP480V370NB
7.4.2 Recommended Torque
Battery Cabinet Model
BP480V370
BP480V370NB
8. Storage and Service
Storage
The battery cabinet must be stored in a clean, secure environment with a temperature less than 40° C (104° F) and a relative humidity less
than 90% (non-condensing). Store the battery cabinet in its original shipping container if possible. Charge the batteries for at least 24 hours
prior to use. Do not rely on the battery cabinet to provide backup power to connected equipment until the batteries are fully charged.
Note: If the UPS system remains off for an extended period of time, it should be turned on periodically to allow the batteries to recharge. The
UPS system should be turned on and the batteries should be recharged at least one uninterrupted 24-hour period every 3 months. Failure to
recharge the batteries periodically may cause irreversible battery damage.
Service
Your Tripp Lite product is covered by the warranty described in this manual. A variety of Extended Warranty and On-Site Service Programs
are also available from Tripp Lite. For more information on service, visit www.tripplite.com/support. Before returning your product for service,
follow these steps:
1. Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading
of the instructions.
2. If the problem continues, do not contact or return the product to the dealer. Instead, visit www.tripplite.com/support.
3. If the problem requires service, visit www.tripplite.com/support and click the Product Returns link. From here you can request a Returned
Material Authorization (RMA) number, which is required for service. This simple on-line form will ask for your unit's model and serial
numbers, along with other general purchaser information. The RMA number, along with shipping instructions will be emailed to you.
Any damages (direct, indirect, special or consequential) to the product incurred during shipment to Tripp Lite or an authorized
Tripp Lite service center are not covered under warranty. Products shipped to Tripp Lite or an authorized Tripp Lite service center must
have transportation charges prepaid. Mark the RMA number on the outside of the package. If the product is within its warranty period,
enclose a copy of your sales receipt. Return the product for service using an insured carrier to the address given to you when you request
the RMA.
Shelves
Dimensions(Height x Width x Depth)
6
2005 x 650 x 1100 mm
6
2005 x 650 x 1100 mm
Individual Battery Unit Model
CSB GPL 121000
N/A
Casters
N
N
Terminal Type
M6 Threaded Insert
138.6 kgf•cm/120.3 lbf•in/13.58 N•m
N/A
23
Weight
Floor Load
1606 kg
1187 kg/m
2
266 kg
1187 kg/m
2
Torque
N/A