5.1.5
To remove the electrical wiring box cover
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling the protruding
part on the top of the cover.
4 Unhook the tab on the bottom and remove the electrical wiring
box cover.
a
b
a
c
a
Tab
b
Protruding part on the top of the cover
c
Screw
5 To re-install the cover, first hook the bottom tab onto the
electrical wiring box, and slide the cover into the 2 upper tabs.
A
117
d
e
48
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin room air conditioner
3P512025-8R – 2019.12
5.1.6
1 Remove 1 screw from the service cover.
2 Pull out the service cover horizontally away from the unit.
3
5.2
5.2.1
a
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape
4 Finish the installation by securing the mounting plate on the wall
a
b
c
a
213
a
h
g
a
170
50
337
770
To open the service cover
a
b
a
Service cover screw
b
Service cover
Installing the indoor unit
To install the mounting plate
measure. Position the end of tape measure at symbol " ".
using M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
c
a
116.5
237
d
f
A
A
a
a
170
48
337
5 Installation
e
(mm)
Installation manual
9