The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60HZ, 300W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
LOCATE AND REMOVE
THE TEN SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
FUEL INPUT
RATING:
GROUNDED
2.13 KG/H
POWER CORD
(4.69 LB/H)
VW-1, 105°C/221°F,
18-3 STANDARD CSA
FIRE POT
INDEX
W : WHITE
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
Y : YELLOW
P : PURPLE
200W, 120V, 2.6 AMP
0.375" X 5.000"
R : RED
K : BLACK
G : GREEN
O : ORANGE
28

ELECTRICAL WIRE DIAGRAM

FAST-BLOW FUSE
5 AMP
GROUND
WW
W
W
AUGER MOTOR
& FEED SYSTEM
120V, 50/60HZ,
0.22 AMP, 2 RPM MOTOR
LOCATE AND REMOVE
THE SIX SCREWS
OF ACCESS PANEL ON
UNDER HOPPER LID
W
W
GRILL
PROBE
R
TEMPERATURE PROBE
MOLEX CONNECTOR
CONTROL BOARD
O
R R
Y Y
W
W
W
LIGHTS
110V, 50W
DRAFT FAN
120V, 50/60HZ,
0.1 AMP, 1 PHASE