TECHNICAL DATA
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
For use on hot air generator the burner must be fitted with control box type 479SE or 539SE.
◆
Burner with CE marking in conformity with EEC Directives: Machine Directive 2006/42/EC, Low Voltage
◆
Directive 2006/95/EC, Electromagnetic Compatibility 2004/108/EC and Efficiency 92/42/EEC.
The burner meets protection level of IP X0D (IP 40), EN 60529.
◆
CE Certification No. : 0036 0259/99 as 92/42/EEC.
◆
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pressure regulator, 2
5 – Vacuum gauge connection
6 – Hydraulic jacks with air-damper
7 – Combustion head adjustment screw
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
10 – Regulation pressure, 1
11 – Economizer
2356
71 / 95 – 240 kW
Light oil, viscosity 4 – 6 mm
Single phase,
Run current 1.5 A – 2750 rpm – 288 rad/s
5 µF
Secondary 8 kV – 16 mA
Pressure: 7 – 15 bar
0.33 kW
D8078
BURNER EQUIPMENT
nd
stage
st
stage
–
6 / 8 – 20 kg/h
2
/s at 20 °C
~
±
230 V
10%
50Hz
Fig. 1
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
4
Screws and nuts for flange
1
Maintenance assembly
1
Screw with two nuts for flange
1
External probe
1
7 pin plug
1
4 pin plug
1
GB
Description