Troubleshooting Tromb Turbo
Problem
The machine is not running.
The warning lights comes on at
startup.
Motor stops immediately after
starting.
Motor runs, but no suction.
Motor runs, but poor suction.
Motor stops during operation
Machine blows dust.
Abnormal sound from machine.
EC Declaration of Conformity
We hereby declare that DC Tromb Turbo complies with the following directives and standards:
2006/42/EC, 2014/30/EU, 2014/35/EU, EN 60204-1:2018, EN1822-1:2019.
Dustcontrol AB
Anna-Lena Berg / CEO
2020-12-18
Cause
Power supply not connected.
Phase fault.
Incorrect fuse.
Suction hose not connected.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Turbo pump overheated.
Motor stops.
Filter loose or damaged.
Peter Söderling / Technical Manager
2020-12-18
DC Tromb Turbo, 99049-A
Action
Connect power supply.
Change phase sequence of electric cable
connected to turbo pump.
Replace with correct fuse.
Connect hose.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Make sure the machine is not throttled and wait
for it to cool down (about 30 min).
Check motor protection switches, cables.
Check and replace as necessary.
Book service.
25