LIFT CORPORATION Sht. 4 of 10 DSG#
6. Remove existing red wire from master disconnect
switch (FIGS. 4-2 and 4-2A).
7. Remove nut from cord grip (Kit item) (FIG. 4-1).
8. Run cab switch cable (Kit item) through vehicle
frame (FIG. 4-2). Next, run cable through cord grip
(Kit item), pump box mounting plate and cord grip
nut (FIGS. 4-2 and 4-2B). Then, insert cord grip into
pump box mounting plate. Tighten nut to secure cord
grip and cable in place (FIGS. 4-2 and 4-2B).
9. Connect white wire from cab switch cable (Kit item)
to circuit breaker (FIGS. 4-2, 4-2C and 5-1). Then,
connect black wire from cab switch cable to master
disconnect switch (FIGS. 4-2, 4-2B and 5-1). Next,
connect 14 gauge red wire (Kit item) to circuit breaker
and master disconnect switch (FIGS. 4-2C and 5-1).
MASTER DISCONNECT
14 GA RED WIRE
(BAT TERMINAL)
CIRCUIT
BREAKER
WHITE WIRE
(AUX TERMINAL)
CAB SWITCH
CABLE
BLACK WIRE
(F2 TERMINAL)
CONNECTING WIRES
© MAXON Lift Corp. 2020
CAB SWITCH
CABLE
CORD GRIP
NUT
ROUTING CABLE
FIG. 4-2B
SWITCH
FIG. 4-2C
M-16-02
MASTER
DISCONNECT
SWITCH
EXISTING RED
WIRE
REMOVING RED WIRE
LIFTGATE
PUMP BOX
PUMP WIRING CONNECTIONS
Rev. A Date: 08/03/20
CORD GRIP
NUT
CORD GRIP
FIG. 4-1
MASTER DISCONNECT
SWITCH
FIG. 4-2A
CAB SWITCH
CABLE
IN-CAB
SWITCH
FIG. 4-2