Trouble Shooting Chart - NSS Enterprises CHARGER 2717 DB Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TABLE 1
BATTERY TYPES
Crown
NSS Part
Part
Number
Number
4491061
1-1470 12
3390361
1-1435
2392111
1-1427 12
6393651
1-1428 12
2392731
1-12145 12
6491931
1-1437
2691501
1-1450
Problem
Machine will not turn on.
Brush motor will not run
or stopped running.
Brush motor will not turn
off when handles are in
neutral position.
Machine vibrates.
Run time is less than
when new.
Battery charger will not
turn on.
Battery Type
Setting
36
215
Flooded/AGM
24 &
6
235
Flooded/AGM
36
24
115 SPE CURVE 0
24
130 SPE CURVE 0
24
100 SPE CURVE 1
24 &
6
200
GEL
36
6
36
350
Flooded/AGM

TROUBLE SHOOTING CHART

Cause
Battery pack is not plugged into machine.
Battery charger is plugged into AC outlet.
The 2-amp fuse is missing or blown.
Circuit breaker is tripped.
Current over load of brush motor has exceeded
set parameters in control system.
Tilt switch failure.
Carbon Brushes worn or not making contact.
The potentiometer is set on the threshold of
neutral or potentiometer has failed.
Pad not centered or torn.
Pad driver damaged and/or out of balance.
Damaged or defective battery or battery pack.
Batteries are not fully charged
Incorrect Battery Type Setting on the charger
Battery charger cord damaged.
Connection not made between battery charger
and battery pack.
The battery charger is damaged.
NOTE: Crown and Trojan AGM batteries should
be charged with the GEL setting.
The charger has been tested on batteries from
the following manufacturers:
Trojan flooded cell
US Battery flooded cell
Deka flooded cell
Crown gel
Concord gel
Discover AGM
Open the battery cover and plug the battery
pack into the machine.
Unplug the battery charger.
Replace 2-amp fuse.
Reset circuit breaker.
Turn off all switches and then turn on the
master switch to reset the control system. If the
problem continues check battery meter for fault
code F42.
Check tilt switch operation. Replace tilt switch if
test failed.
Have an authorized NSS Service Station check
carbon brushes and replace if necessary.
Have an authorized NSS Service Station reset
the potentiometer to neutral or replace.
Center pad. Change torn and worn pad.
Check pad driver for damage and replace if
necessary.
Check for fault codes on the battery charger
during battery charging. Have an authorized
NSS Service Station check the batteries and
replace as necessary.
Charge batteries until the green LED indicates
the charge cycle is complete.
Ensure the charger is set according to the type
of batteries installed.
Check for cord damage and replace if
necessary. DO NOT try to repair it.
Check connections at battery pack for corrosion
and loose or broken wires.
Have an authorized NSS Service Station check
and replace if necessary. DO NOT try to repair
it.
Solution

Publicidad

Tabla de contenido
loading

Productos relacionados para NSS Enterprises CHARGER 2717 DB

Este manual también es adecuado para:

Charger 2022 db

Tabla de contenido