5.6 Unit wiring

Note: The cross-sectional area of the conductor selected by user must not be less than the specifications listed
in the table. If the the user's power cord is too far away from the unit, make a corresponding increase in the
cross-sectional area of the line group to ensure the normal power supply.
Power suppiy line specifications
Outdoor power supply line
Name
Model
Single phase
18K model
Single phase
24K model
Single phase
≥36K model
3-phase
≥36K model

5.7 Fault code

Table 1: Indoor unit fault is displayed
When unit is standby after first time power on,running light flash slowly,after operation,all
the lights off when
the unit is off or standby.
When unit is running,running light flashes,digital tube shows setting temperature in cooling
and heating
5 Electrical Installation
.
Indoor power supply
(quantity ,diameter)
line (quantity,diameter)
H05RN
F
-
3 x 1.5mm²
3 x 2.5mm²
3 x 4mm²
5 x 2.5mm²
Indoor /outdoor
connection line (quantity,
Diameter)
H05VV-F
/
4 x 1.0mm²
/
4 x 1.0mm²
4 x 1.5mm²
/
/
4 x 1.5mm²
30
method
Power supply
Outdoor Power Supply
Outdoor Power Supply
Outdoor Power Supply
Outdoor Power Supply