Descargar Imprimir esta página

Infiniton GAS4RO Manual De Usuario página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Instructions forinstallation
Setting the minima
The flame on the small output is regulated in the factory. When the injec-
tors have been replaced or there are special mains pressure conditions, it
may be necessary to regulate the minimum again. The operations neces-
sary to perform this operation are the following:
light the burner
turn the knob to the minimum position
take out the knob (and gasket if there is one)
using a suitably sized screwdri-
ver turn the regulation screw insi-
de or by the side of the tap shaft
until a small regular flame is
obtained
put the knob back on and turn it
quickly from the maximum posi-
tion to the minimum position,
checking that the flame does not
go out
for burners with safety valve make sure that the regulation obtained is
sufficient to maintain heating of the thermocouple. If it is not increase the
minimum.
Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the screw
inside or next to the gas tap pin
The operations described above can easily be performed whatever the
positioning or fastening of the hob to the cabinet.
THE BURNERS REQUIRE NO REGULATION OF THE PRIMARY AIR.
.
14 - ENGLISH

Publicidad

loading

Este manual también es adecuado para:

Gg-419