Troubleshooting

Trouble
fails to go on.
Unit operating,
but no tempera-
ture at the tip
The tip fails to
reach the desired
temperature.
Possible cause
• Control unit not switched on.
• Power supply interrupted.
• Plug not fully inserted in the control unit.
• Faulty control unit.
• Faulty transformer.
• Short circuit in the tip.
• Tip not properly screwed in.
• Tip / handpiece contact contaminated.
• Faulty tip.
• Handpiece cable not properly plugged
into the control unit.
• Plug on handpiece cable shows signs of
corrosion.
• Incorrect power supply to the tip because
the OEM mains power supply unit is not
being used.
Corrective action
• Switch the control unit on at switch "A".
• Check the power supply and reconnect, as required.
• Push the plug in until it unmistakably locks in place.
• Have unit replaced by Service Department.
• Replace the tip.
• Faulty heater handle --> Replace with spare (refer to the
• Hand tighten tip.
• Fully insert the handpiece cable into the socket until the
cable locks in place.
• Reinsert the plug, clean the contacts, if required.
• Use the OEM mains power supply unit.