Alternate the screwing on both screws in order to have a homogeneous tightening couple.
- Your valve is now firmly attached to the tank and the waterproofness is ensured.
- Except on ref. 105799, unscrew the nut situated on the side of the valve, and put the manometer (fig.1, n°4) at this
place, after putting Teflon on the thread.
• FIXATION OF THE PUMP ON ITS BASE
- The pump is packaged in its original box for a higher safety. It is electrically wired and ready for use.
- Place the pump on its bases (fig.2) at the level of the fixation holes. Fix the pump using the screws, plastic rings & nuts.
• Set both bases together (pump and tank) with the aid of the clips, according to figure n°2.
• Concerning the pump's running, please refer to user manual.
REF : 103458-103460/105799
• 5/2 threaded unions (fig.2) 1''1/2 - 32/38
• 5 stainless clamp collars (fig.2)
• 1 flexible pump-filter connecting hose (fig.2)
• 1 PTFE roll
Wrap the threading of the unions with Teflon in order to ensure a perfect waterproofness.
• Except for ref.105799
'RETURN' (fig.1, letter S) : outlet towards inlet(s). // 'PUMP' (fig.1, letter E) : filter entry, corresponding to pump
• Screw on the two threaded unions on the pump :
Vertical : pump discharge
Horizontal : pump suction
• Thread the two stainless collars on the flexible PVC
hose. Connect the hose, on one side with the valve link
'PUMP', and on the other side with the vertical link of
the pump (pump discharge).
• Check if the hose is driven at the maximum in the
unions.
• Repeat the operation to link together the pump suction (horizontal link) to the skimmer(s) and the valve
outlet ("RETURN") to the inlet. Provide a drainage pipe on the "WASTE" outlet for liquid waste.
• At the time of the installation, we advise you to provide a stopping valve for the suction and another one for the
pump discharge, in order to be able to isolate the filtering unit from the pool (especially for the pump's
basket cleaning).
The supplying electrical installation must comply with the European and local standards in force and must be done
by a skilled electrician. Please refer to the annexed pump instructions for additional details.
The whole installation must be provided with an earth plug as well as with a 30 mA differential switch.
Caution : the pump must never be used without water. Always prime the pump before starting up the pump for the first
time. In order to facilitate the priming, put the multi-port valve on the "RECIRCULATION" position and start the pump
for a few seconds. Please refer to the installation manual of the pump.
• The first operation consists in checking all connections, collars and unions as well as the water level in the pool.
•Check that the pump strainer contains its basket, that the strainer is filled with water and that the transparent
lid is well screwed on.
III. INSTALLATION OF THE PUMP
IV. HYDRAULIC CONNECTIONS
COMPONENTS SUPPLIED :
, screw on the first three threaded unions on the valve, on the provided locations :
*
* The ref.105799 has a valve integrating the fluted connections.
V. ELECTRICAL CONNECTIONS
CAUTION : NEVER MANIPULATE THE VALVE WHILE THE PUMP IS ON.
REF : 103461/103463
• 3 threaded connections (Fig.2) 1''1 / 2 - 32/38
• 3 stainless steel clamps (Fig.2)
• 1 connection kit pump / filter + threaded ends
• 1 PTFE roll
discharge // 'WASTE'
• Tighten the stainless collars in order to ensure their
waterproofness.
• Screw the barbed fitting on the pump suction
• Screw the connection kit one hand on the valve
by putting the TCB band, on the other hand on the
pump discharge (vertical).
VI. THE SETTING
7 | NOTPSB-INDG-0117