TERMINAL DESCRIPTION:
B1 power relay input (output 4)
B2 power relay output (output 4)
A1 power relay input (output 3)
A2 power relay output (output 3)
Software Version 3.0

STANDARD OPERATION

Accessory for the systems DIGIBUS, Digit 2 Video and for digital intercommunicating systems (6221 - 6935/A) with 4 program-
mable outputs with 4 or 8 digit codes (for Digit 2 Video systems 4-digit codes only) for a minimum activation time of 1 second
and maximum 9999 seconds, independent for each output. The outputs are activated following reception of a digital command
on one of the two input lines (terminal 1 or 6, for Digit 2 Video systems terminal 1 only) and the type of operation set on the Dip
Switches as described in Table 1.
Operation Activation
Command only
Number and command
Shutdown with reset
Window activation
On / Off operation
Operation description:
- COMMAND ONLY
Activation following reception of a specific command. The programmed output activates for the set time whenever this speci-
fic command is received, regardless of the associated number (e.g. when the "lock" key is pressed on any interphone in the
system).
- NUMBER AND COMMAND
Activation for a set time only after reception of a number and relative command (e.g. call from entrance panel to interphone
1234 or when key F1 is pressed on interphone 87654321)
- SHUTDOWN WITH RESET
Shutdown of all outputs each time the device receives a RESET signal, even if the activation time (which remains valid) has
not elapsed.
- WINDOW ACTIVATION
Activation for set time after reception of a command with a number inside the window INITIAL USER - END USER program-
med accordingly
- ON /OFF OPERATION
The output changes status (if on sets to off and vice versa) on reception of the memorised code. The activation time is irrele-
vant.
Parameter
Minimum Maximum
Output 1 time
1 s
Output 2 time
1 s
Output 3 time
1 s
Output 4 time
1 s
Initial User
1
Final User
1
Device Number
0
*for 4-digit digibus systems or digit 2 video systems the value is 9999
LED S2
Dip 1
Dip 2
Dip 3
OFF
---
---
ON
---
---
---
ON
---
OFF
---
ON
---
---
---
Default
9999 s
1
9999 s
2
9999 s
3
9999 s
1
99999999*
1
99999999*
99999999*
99999999*
0
LED B LED A
DIP SWITCH
KEY P2
Dip 4
---
---
---
---
Table 1. Dip Switch settings
ON
(---indicates that the dipswitch position is irrelevant)
Description
Output 1 activation time
Output 2 activation time
Output 3 activation time
Output 4 activation time
Initial User of Window
Final User of Window
Device Number (#)
(#) Special parameter
LED S1
TERMINAL DESCRIPTION:
1
digital line
6
Second digital line
4
Earth
5
+12V DC supply voltage
S1 open collector output (output 1)
S2 open collector output (output 2)
KEY P1
KEY RES
Table 2. Parameter