Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ERROR CODES

DESCRIPTION
-----
Overload
Err 1
Date Setting Error
Err 2
Time Setting Error
Err 4
Zero Setting Error
Err 6
A/D out of range
20 OF 62
ERROR CODES
RESOLUTION
Remove weight from the scale.
If the problem persists contact Uline Customer
Service.
Enter date using correct format.
Format: yy:mm:dd
Enter time using correct format.
Format: hh:mm:ss
The scale was outside the normal zero setting
range either when it was turned on or when the
ZERO key was pressed.
Remove weight from the scale and try again.
Use the TARE key to set the display to zero value.
If the problem persists contact Uline Customer
Service.
The values from the A/D converter are outside
the normal range. Remove weight from the
scale if overloaded, make sure fork cover plate
is attached.
Indicates the load cell or the electronics may
be faulty.
If the problem persists contact Uline Customer
Service.
1-800-295-5510
uline.com
0721 IH-4564

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido