The burner cannot be lighted or the flame is not uniform around the burner.
Check to make sure that:
The gas holes on the burner are not clogged;
All of the movable parts of burners are fixed correctly;
There is no air flow around the cooking surface.
The flame does not keep lighting to the burner with thermocouple.
Check to make sure that:
You press the knob all the way;
You keep pressing the knob for enough time to activate the thermocouple.
The gas holes are not clogged in the area corresponding to the thermocouple.
The flame goes out while turning knob to "Low" setting.
Check to make sure that:
The gas holes are not clogged.
There is no air flow around the cooking surface.
The minimum has been adjusted correctly (see the section entitled "Minimum Regulation").
The cookware is not stable.
Check to make sure that:
The bottom of the cookware is perfectly flat.
The cookware is centered correctly on the burner.
The support grids have not been inverted.
After checked all of these, the gas hob still does not work properly, please call the Customer Service Center
and inform them of:
Tile type of problem.
--
The gas hob model number (Model....) as indicated on the packing carton.
--
Never call the technicians who is not authorized by your supplier, and refuse to use the spare parts which
are not from manufacturer.
The following instructions are directed at the qualified installer, so the installation and maintenance
procedures may be followed in the most professional and expert manner.
Important: Unplug the electrical connection before performing any maintenance or regular upkeep
work.
Positioning for gas hob
Important: this unit may be installed and used only in permanently ventilated rooms.
The following requirements must be observed:
a) The room must be fitted with a ventilation system which ventilates smoke and gases from combustion to
the outside of rooms.
This must be done by hood or electric ventilator.