Cisal H200013 Información Técnica página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
parts with a brush and rinse;
in case of calcareous incrustations; dip the thermostatic
valve in the product Cisal
Master Libby (article ZA00800) and then rinse.
- Replacement of the thermostatic valve : insert the new
thermostatic valve; by screwing it with a 22 mm wrench.
- Insert the lock nut (6) with the notch turned upwards and
aligned with the reference placed on the thermostatic mixer
(ref. picture 2/A).
- Assemble the adapter (5) again.
- Open the cold and hot water inlets.
CALIBRATION
- Take the temperature of the mixed water.
- Bring the temperature of the mixed water to a value
between 38 °C and 40 °C by rotating the rod of the
thermostatic valve.
- Insert the handle (4) with the indication of the 38 °C aligned
with the reference placed on the thermostatic mixer (rif.
fig.2/B).
- Tighten the screw (3) and mount the handle (2) again; by
tightening the pin (1) with a 2 mm Allen wrench.
REPLACEMENT OF THE CERAMIC HEADVALVE
H200013 – H200044 – HY00408
LS00408
AC00408
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the
flow rate (3)
- Disassemble the handle (3); removing the small cap (1) and
unscrewing the screw (2)
- Remove the adapter (4)
- Disassemble the ceramic headvalve (5) by unscrewing it
with a 17 mm wrench.
- Mount the new ceramic headvalve; by screwing it down with
a 17 mm wrench
- Assemble the adapter (4) again.
- Rotate the rod of the ceramic headvalve clockwise up to
its lock.
- Insert the handle (2) with the button turned forwards.
- Tighten the screw (2) and assemble the small cap again (1).
REPLACEMENT OF THE CERAMIC HEADVALVE
BQ00408
(ref. picture 9)
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the
flow rate (4).
- Remove the handle (2) by unscrewing the pin (1) with a 2
mm Allen wrench.
- Remove the handle (4) by unscrewing the screw (3)
- Remove the adapter (5).
- Remove the ceramic headvalve (6); by unscrewing it with a
17 mm wrench.
- Assemble the new ceramic headvalve; by screwing it with a
17 mm wrench.
- Mount the adapter (5) again.
- Rotate the rod of the ceramic headvalve clockwise up to
its lock.
- Insert the handle (4) with the button turned forwards.
- Tighten the screw (3) and mount the handle (2) again by
tightening the pin (1) with a 2 mm Allen wrench.
If over time there is a reduction of the maximum flow-rate,
clean or replace the filters and the aerator fitted on the
(ref. picture 6)
(ref. picture 7)
(ref. picture 8)
spout.
See the " Master Libby" leaflet enclosed in the packaging
for details of the maintenance of
the finishings.
-12-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H200044H200408Ls00408Bq00408Ac00408

Tabla de contenido