This section describes the connection of the UVC clarifying unit Bitron with a pump fed system.
• Please adhere to the instructions for use of the flow-through filter.
How to proceed:
4.
0.
F, G
1. Insert the outlets with flat seals through the holes in the container wall.
2. Fitting the inlet:
− ProfiClear Premium: First screw the adapters onto the outlets and hand tighten. Then screw the 30° inlet bends
with the union nuts onto the adapters and hand tighten. Ensure that the openings point downward.
− ProfiClear Classic / BioSmart: Screw the inlet nozzles with the O rings onto the outlets and hand tighten.
3. Closing the bypass (optional):
− ProfiClear Premium: Screw the cover cap onto the outlet instead of the adapter and inlet bend.
− ProfiClear Classic / BioSmart: Screw the cover cap onto the outlet instead of the inlet nozzle.
4. Connect the Bitron to the filter pump. (→ Connecting the inlet)
BioTec ScreenMatic
• Please adhere to the instructions for use of the flow-through filter.
5.
How to proceed:
0.
H
1. Insert the outlets with flat seals through the holes in the container wall into the distributor.
2. Screw the distributor nuts with O rings onto the outlets and hand tighten.
3. Connect the Bitron to the filter pump. (→ Connecting the inlet)
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

• Prior to reaching into the water, switch off the mains voltage to all units used in the water.
• Switch off the mains voltage prior to carrying out work on the unit.
Note!
If the water flow is suddenly interrupted downstream of the outlet (e.g. with a slide valve), this can lead to a
brief increase of pressure of more than 1 bar (water hammer).
Possible consequences: The unit may be damaged.
Protective measures:
• Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a filter system,
first take the filter system out of operation.
• Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a filter system,
start up the filter system last.
• Install the slide valve upstream of the inlet.
When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off for at
least 36 hours so as not to impair their efficacy.
Prerequisite
• Switch the pump on first, then switch on the UVC clarifying unit.
• Check all connections for leaks.
Switching ON/switching OFF
• Switching on: Insert the power plug into the socket.
− The unit switches on immediately.
• Switching off: Disconnect the power plug.
Check the function.
I
• The function display is lit when the UVC lamp is switched on.
• An alternating light/dark blue glow in the inspection window indicates that the cleaning rotor is rotating.
10
GA_30822_03-14_ Bitron_C_USA.pdf10 10
06.03.2014 09:30:22