GB T5 AUTO SHORT Hz - 230V - 50HZ - 6 Nm 17 rpm.
S.A.S. au capital de 5 000 000
Installation
1
- Recommendations:
- The motor torque must be selected according to the shutter's characteristics. Do not oversize the operator.
- The use of automatic locking devices (VAR, VAS or EASYLINK) and stops on the final slat is mandatory in order to ensure proper working
of the motor.
- To receive information regarding the compatibility of the motor and the roller shutter or/and accessories, contact the roller shutter
manufacturer or SIMU.
- Drilling of the tube:
55
20
48
4
- Assembly :
1
Compatible transmitters
2
1
2
3
1 : Hz wall transmitter
3 : Hz timer
2 : 1 / 5 channels Hz transmitters
4 : Hz "long range" transmitter
Test
3
For operation 3.1, work with only one unprogrammed receiver connected to the electrical network.
3.1
ON
3.2
a
>>
b
>>
>>
Memorizing the automatic settings
4
- Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
370
47
385
min.
Ø4,8 x 10
5
ACIER-STEEL-STAHL-ACERO-ACCIAIO
Ø5 x 10
4
2
3
Transmitters range :
- 1, 2 and 3 : 20 m through 2 concrete walls.
- 4 : 40 m through 2 concrete walls.
4
- 12 transmitters max. per receiver.
- Do not position the transmitter near metal surface or
structure in order to avoid range losses.
>>
>2s
>>
>>
4.1 - Simultaneously press the UP and DOWN keys of a Hz transmitter. The motor will run for 0,5
2s
4.2 - Press the "stop" key for 2 s. The motor will run for 0,5 second in one direction and then in the
355
4xØ5 /90°
9910013
1
9910014
- Switch on the receiver.
- Then simultaneously press the Up and Down keys of a transmitter. The motor will run for half
a second in one direction and then in the other. The transmitter now controls the receiver in
unstable mode for operations 3.2, 4 and 5
Checking the motor rotation direction:
a - If the shutter goes up, move to the next step (§4).
b - If the shutter goes down, reverse the rotation direction by pressing STOP
for at least two seconds.
If you do not want to programme the transmitter that has been used
for the test later on as the receiver control point, switch off the
>>
power supply of the receiver for two seconds and then perform ope-
ration 3.1 with a new transmitter before you perform operation 4.
second in one direction and then in the other.
other. The operation is completed. Go to stage §5.
Read carefully these instructions
24
45
120
0.2m
3.00m
1
2
2
3
2
Location of the "PROG" key on Hz transmitters:
1
2
PROG
5057768C
before any use.
N
Blue
L
Brown
PE
Green/yellow
2
3
1
4
3
4
PROG
1 / 2