Important Information
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. To reduce the risk of electrical shock, connect only to circuits
protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes.
Grounding is required. The unit should be installed by a qualified service representative, and grounded.
Building materials and wiring should be routed away from the blower body and other heat-producing
components of the unit.
Install to permit access for servicing.
A pressure wire connector marked "Earth/Ground" is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
Pressure wire connectors are provided on the exterior of the junction box or control within this unit to permit
connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to
comply with local requirements.
Electrical Requirements
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or
similarly qualified persons in order to avoid a hazard.
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protects against line-to-ground shock hazard. Use a 220-240 V, 15 A, 50/60 Hz
dedicated service for the bath with airjets.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors supplying this equipment.
Install this unit in accordance with the Canadian Electrical Code, Part I.
Product Notices
WARNING: Risk of personal or property damage. Unauthorized modification may cause unsafe
operation or effect performance of the bath with airjets. Do not relocate the blower motor, or
make other modifications to the bath system in the absence of kit or other published instructions, as
this could adversely affect the performance and safe operation of the product. Kohler Co. shall not
be liable under its warranty or otherwise for personal injury or damage caused by any such
unauthorized modification. Refer to the "Before You Begin" section for blower motor relocation
requirements, recommendations, and section coverage information.
NOTICE: Keep the area around the blower motor clean and free of debris. Ensure that the area around
the blower motor is free of sawdust, insulation, dirt, or other small loose debris. Such material could plug
the blower motor air ducts and reduce the air flow through the blower.
Factory Assembled Features
Factory assembled components include a blower motor, air harness, control, check valve, butterfly valves,
chromatherapy lights (if provided), electrical harnesses, and an illuminated user keypad. Other than power
wiring and plumbing, no assembly is required.