Use And Maintenance Instructions; Operation; Switching On The Machine; Operational Cycles - ASBER BC-GN 03 Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
EN

5. USE AND MAINTENANCE INSTRUCTIONS

BEFORE STARTING THE APPLIANCE, PLEASE READ THE INSTRUCTIONS
CONTAINED IN THIS MANUAL CAREFULLY.
THE APPLIANCE IS EXCLUSIVELY FOR PROFESSIONAL USE, AND SHOULD
ONLY BE USED BY QUALIFIED PERSONNEL.

Operation

The steps required to optimize the operation of your machine are shown below, with all the available
options.

Switching on the machine

The control panel has an On/ Off switch and one thermostat. In the Figure 5 you can see them in detail.
Once the interior of the cabinet has been cleaned, connect it to the electrical network and turn
the switch (1, Fig.5) to ON. The switch must be illuminated.
If the appliance is on and no cycle is running, the DISPLAY (Fig.5) shows the temperature of the
chamber.
If there is no active cycle, after 10 seconds without any icon being pressed, DISPLAY (Fig.5) will
automatically turn off, except for the low consumption LED. To turn the display on again, press
any icon.
If there is 60s elapse time without any icon being pressed, the display will show "Loc" and the
keyboard will automatically lock. To unlock the keyboard, press any icon for 1 second. The display
will show "UnL".

Operational cycles

The blast chiller you have adquired is controlled by an electronic timer with a chamber temperature probe,
which allows 2 blast chilling methods. First one, time controlled cycle, in which the blast chilling cycle
ends once the time defined for the process has elapsed and second one, temperature controlled cycle,
whose process ends, once the temperature sensor inserted in the food reaches the defined temperature.
In turn, there are 2 blast chilling processes, depending on the final temperature to be reached, refrigeration
and freezing, which can be accessed by pressing the SET button (14, Fig.5).
PoS
nEG
PoS
nEG
5.1.2.1
Time controlled chilling cycle
To run a time controlled blast chilling cycle follow these steps:
1.
Make sure that the keyboard is not locked and that no chill or defrost cycle is active.
2.
Press SET button (14, Fig.5) to choose between a refrigeration chilling process "PoS" or freezing chilling
process"nEG" and ensure that the
refrigeration cycle lasts 90 minutes, while freezing cycles lasts 240 minutes.
3.
OPTIONAL: Parameters related with cycle duration, setpoint of the chilling cycle and conservation cycle
setpoint can be adjutasted.
o
Press SET button to select a cycle
Refrigeration, time controlled cycle
Freezing, time controlled cycle
Refrigeration, temperature controlled cycle.
Freezing, temperatura controlled cycle
Press START/STOP button in the following 15 seconds.
Press button DOWN
to see default cycle duration and modify it. In order to change the value press UP
(11, Fig.5) or DOWN (12, Fig.5). Press again SET button (14, Fig.5) to exit and continue to
the next step.
TIME CONTROLLED CYCLE
(12, Fig.5), before 15 seconds and press button SET (14, Fig.5)
22
icon (10, Fig.5) blinks. By default,