Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTRUCTIONS FOR USE
DESCRIPTION OF SIMPLIFIED ELECTRONIC TIMER 366/604
The system has a valve with a timer where all operation controls are located.
CONTROLS
A Start manual regeneration
B Display
C Time setting
D Salt consumption setting
E Programming regeneration at days interval
F Cap closure
G Indication of regeneration delay/decimal value
H Position indicator
I
Camshaft indicator
COMMISSIONING
In order to use the system in a safe way, it is fundamentally important to follow the indications of the next paragraphs, as
well as checking the protection and safety devices before each use.
IN ORDER TO START OPERATING THE SYSTEM, MAKE SURE THAT:
• The water connections are compliant with the standards;
• The electrical connections are compliant with the standards.
OPERATING THE SOFTENER
warning

IMPORTANT

Before operating the softener clear the air form the system and remove the resins that, at the beginning, could give a yellowish/red-
dish colour to the water.
PROCEDURE
1. Turn on the timer and start up the forced regeneration by pushing the button
2. Open the water supply tap.
3. Check the discharge device so that air goes out before water for 1 minute in total.
4. Close the supply tap and make the regeneration stages proceed by keeping the
time for 4 seconds and than release.
5. Let it continue in automatic mode until the valve returns to its initial position.
6. Fill the vat with salt, add 10L of water and operate the system by opening the supply and the output taps, closing the by-
pass.
If the water is still a bit coloured, leave it flush from the output tap until it gets clear.
4
A
I
H
G
.
and
buttons pushed at the same
B
C
D E
F

Publicidad

loading

Este manual también es adecuado para:

Eco 8Eco 5Eco 12Lf3010241Lf3010259Lf3010242