MAINTENANCE
Immediately repair possible failures or damages to covers and electric appliances.
OPERATIONS BEFORE COMMISSIONING:
• General visual inspection (evident warps or damages of structure, protections, etc.);
• Check of the conditions of the power supply cable.
The softener does not require any kind of ordinary maintenance but the check and refill of salt.
The hour set must correspond to current time. It is important to check the softener periodically to safeguard the efficiency
of connected devices.
These operations include checking water hardness and input and output capacity, the right execution of the different stages
and the conditions of resins to replace them if necessary.
warning
DANGER
Never perform the operations above with wet or damp hands.
PERIODIC CHECKS
AFTER THE FIRST 6-12 MONTHS, AND THEN EVERY 6-12 MONTHS:
Clean the salt container following the procedure hereunder:
• Remove the remaining salt from the bottom;
• Clean all the walls of the container from muddy, oozy or dry salt deposits;
• Rinse several times with running water using a water disinfectant such as Amuchina and a sponge;
• Rinse again, add the same quantity of water and then add the salt.
Periodically clean the washable cartridge of the pre-filter by removing all impurities from the bottom and from the surface
of the cartridge. It is sufficient to use running water.
TROUBLE SHOOTING
PROBLEMS, CAUSES AND SOLUTIONS
PROBLEMS
Regeneration starts at a wrong time
The programmer stops during
the regeneration cycle
The softener regenerates or discharges
water continuously
CAUSES
Timer set up incorrectly
Burnt out engine
Power supply failure
Incorrect voltage or frequency
The camshaft is blocked
Excessive supply pressure
Valve 3 or 4 or both remain open
Power supply failure
Blocked or burnt out engine
SOLUTIONS
Set up the timer
Replace
Check connection
Check the right voltage or frequency
Remove damaging bodies from the valve
or from the camshaft
Install a pressure adjuster
Remove damaging bodies that could
make the valves remain open
Check the voltage
Replace the engine
9

Publicidad

loading

Este manual también es adecuado para:

Eco 8Eco 5Eco 12Lf3010241Lf3010259Lf3010242