Lift spring and remove brush. Install new brushes. Clean
carbon brush holders, making absolutely sure not to
change the arrangement of the elements of the carbon
brush assembly. Fit handle halves and fasten with four
screws. Repeat this change on the opposite side, making
absolutely sure to avoid both handle halves from being
opened at the same time.
4.1.2 c
leAning the slide disc
Loosen the screw, and remove the tool.
Twist off the slide disc. Clean all parts thoroughly. Apply a
small quantity of commercial multipurpose grease to the
ball guides at the angle head lock. Install the parts by fol-
lowing the above instructions in reverse order.
4.2 s
pAre pArts
See page 2.3.
4.3 r
epAir
If despite strict observance of the manufacturing and test-
ing method the tool should happen to fail, it must be re-
paired by an authorized SUHNER agency.
Any replacement needed for the connecting line must be
installed by the manufacturer or its agent if safety risks are
to be eliminated.
4.4 w
ArrAnty
In the event of the tool being improperly handled, used
for purposes for which it is not intended and/or of the ser-
vice and maintenance instructions not being observed by
non-authorized persons, no warranty shall be in effect for
damages/consequential damages.
Complaints can only be honored if the machine is re-
turned in the undisassembled condition.
4.5 s
torAge
Temperature range during operation: -15°C to +50°C
Max. relative air humidity: 90% at +30°C, 65% at +50°C
4.6 d
/ e
isposAl
nVironmentAl compAtiBility
The machine consists of materials which can be recycled
in a recycling process.
Before disposal, render the machine unusable.
Do not throw the machine into the garbage collec-
tion
According to national regulations this machine must be
recycled in an environmentally-friendly manner.
19