Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
htr
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre.
The opening of the STOP input stops the motor. All the safety inputs are deactivated.
Off: Automatic/semiautomatic function
Selects the operating mode of the blinking light during the time TCA
ltca
On: Blinking light on during TCA
Off: Blinking light off during TCA
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the photocell is
released, the motor restarts in the opening phase. In closing phase: the contact opening causes
phcl
the motor stop. When the photocell is released, the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the immediate reversion
of the operation direction (open).
Enables OPEN input as Pedestrian input (Partial parameter TPED opening).
opcl
On: OPEN input enabled as pedestrian input (PED).
Off: No modification to the OPEN input
Enables or disables checking of photocells on PHOT input, active both in closing and in opening.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See Fig.23
TST1
- "PHOTO TEST". (AUX1=3)
Off: Check of photocells each time a manoeuvre is disabled. This setting requires maintenance
of photocells every 6 months.
Enables or disables the check of photocells on PHOT C input.
On: Check enabled. If the check fails, no manoeuvre will be enabled. (AUX1=3)
tst2
Off: Check of photocells each time a manoeuvre is disabled. This setting requires maintenance
of photocells every 6 months.
Changing the operating mode of the PHOT OPEN and BAR inputs in the event the sensitive
edges are installed on the mobile opening and closure edges (see Fig.21).
On: The PHOT OPEN input assumes a similar function to the BAR input, but inverts motion for
3s only during the opening phase. The edge connected to the BAR input is only active during
bar
the closure phase.
Off: Intervention of the sensitive edge connected to the BAR input stops movement of the door
and inverts for approx. 3s, both opening and closure.
The PHOT OPEN input re-starts functioning of the photocell active on opening.
The "forced opening in case of power cut-off" function is activated or deactivated (it can be
activated only with connected and operating emergency batteries).
On: Activated function. In the event of power failure, before the emergency battery completely
aopf
discharged, the control unit causes an opening operation.
The door remains open until the power supply is back.
Off: Deactivated function.
The opening direction of the motor is selected:
minv
On: Right side motor mount
Off: Left side motor mount (fig.20)
Enables or disables remote radiotransmitters learning, as indicated in the paragraph "Remote
transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the PED function.
Press the transmitter key, which is to be assigned to this function.
ped
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested.
RTR
By selecting this function the receiver goes into waiting (Push) for a new PGM pressure to confirm the operation.
At end of erasing the OK message is displayed
26
8.4.3) RADIO (RADI)
FUNZIONE
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)

Publicidad