3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted as a flushmount
on a regular (no-slope) ceiling only. Downrod
installations are not available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch
is turned to the OFF position.
WARNING: Failure to disconnect power supply
prior to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight
of the fan. Ensure outlet box is clearly marked
"Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do
so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (green or bare) is present.
Install hanging bracket to outlet box using
original screws, spring washers and flat washers
provided with new or original outlet box. * Install
rubber cushions between outlet box and
hanging bracket to reduce vibration of metal to
metal surfaces. Pull electrical wiring from outlet
box through center hole in the hanging bracket.
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as
this will support the fan.
blade edge
30
inches
7 feet
(76cm)
(2.13m)
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
rubber cushions
hanging
bracket
spring washers
outlet box screws
page 4
12ft. - 20ft.
(3.66m - 6.1m)
downrod
installation
flat washers