Kohler K-108 Instrucciones De Instalación página 4

Grifos con perforaciones separadas
Ocultar thumbs Ver también para K-108:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ALL DRAINS
S Insert the stopper into the flange.
S Remove the body nut from the seal hole.
S Fit the short end of the rod into the body seal hole
and under the stopper for regular installations;
through the hole for vandal-resistant installations.
S Loosely secure in place with the body nut.
S Remove and adjust the stopper so the stopper lifts
about 3/8" (1cm) when opened. To adjust, loosen
the stopper nut and shorten or lengthen the stopper
as needed. Re-tighten the stopper nut.
S Handtighten the body nut.
S Apply thread sealant to the tailpiece. Thread the
tailpiece into the body and securely handtighten.
S Slide the clip and the link onto the rod with the
thumb screw facing toward the back of the lavatory.
S To move the link to the proper position, squeeze the
clip and slide it along the rod.
S Push the rod down (open position).
S Slide the faucet lift rod through the hole in the spout
and through the hole in the link.
S Tighten the thumb screw on the link so the lift rod
knob is 1/2" (1.3cm) above the lift rod hole.
IF THE LAVATORY IS NOT INSTALLED, INSTALL IT AT THIS TIME. BE SURE TO
FOLLOW ALL INSTRUCTIONS PACKED WITH THE LAVATORY.
SUPPLIES AND STOPS
S Connect the supply tubes to the faucet end
bodies and supply stops. (Left is hot – right is
cold.)
S Tighten all connections.
A
1010441-2-
Body
Nut
Rod
Seal Hole
Apply Thread
Sealant
Thumb Screw
Clip
Rod
Supply Tube
Kohler Co., Kohler, WI U.S.A.
4
Stopper
Stopper
Nut
Body
Tailpiece
Link
Supply Tube

Publicidad

Tabla de contenido