11) Technical specifications
Power input
Max. absorbed power
Emergency Electricity supply
Maximum motor current
Service power output
Phototest output
Flashing lamp output
Gate open indicator output
STOP Input
Working time
Pause time
Pre-flashing time
Leaf delay in open cycle
Leaf delay in close cycle
2nd motor output
Maximum cable lengths
Operating temperature
16
: POA1 Control unit
230Vac ±10% 50÷60Hz
: POA1/V1 Control unit
120Vac ±10% 50÷60Hz
: 170 VA
: for PS124 buffer batteries
: 3A with a "level 6" current sensitivity cut in)
: 24Vdc 200mA maximum current (the voltage can range from 16 to 33Vdc)
: maximum current 24Vdc 100mA (the voltage can range from 16 to 33Vdc)
: for flashing lamp 24Vdc, maximum power 25W (the voltage can range from 16 to 33Vdc)
: for indicator lamps at 24Vdc maximum power 5W (the voltage can range from 16 to 33Vdc)
or electric locks 12Vac 25W
: for NC contacts or constant resistance 8,2KΩ +/- 25%
: automatic detection
: programmable at 5, 10, 20, 40, 80 seconds
: programmable at 2, 4, 6, 8, 10 seconds
: programmable at 5, 10, 20, 30 and 40 % of working time
: Automatic detection
: for POP PP7224 motors
: electricity supply
30m
: 2nd motor
15m
: other inputs/outputs 50m
: aerial
10m
: -20÷50°C