Device Configuration; Reset Of The External Device Monitoring (Edm) - SICK C2000 RES Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
Chapter 4
30
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Electrical installation and
configuration
4.1

Device configuration

The device configuration is described in the following chapters of the C2000 operating
instructions:
chapter 5.4.1 Configuration of the device self test
chapter 5.4.2 Configuration of the cyclic system test
chapter 5.4.5 Configuration of the external device monitoring (EDM)
The beam coding function is not available on the C2000 RES/EDM safety light curtain.
The restart interlock function RES is always active and cannot be de-activated.
4.2

Reset of the external device monitoring (EDM)

To reset the external device monitoring, connect (EDM) PIN 1 on the receiver to GND
(see chapter 3.5 in the "C2000 Safety Light Curtain" operating instructions).
Addendum Operating Instructions
C2000 RES/EDM
8011906/TI60/2010-02-12
Subject to change without notice

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C2000 edm

Tabla de contenido