Fig. 1 - Abb. 1
Kit purpose
The purpose of the hot water heating coil
is to provide for heating in the cooling only
split systems by connection to a traditional
heating system.
The kit includes an antifreeze thermostat
to protect the coil against any failure due
to ice on the circuit.
The thermostat stops the system if
temperature reaches + 3°C and then put it
back to 12°C.
Installation
IMPORTANT:
Disconnect the mains power supply
before performing any operation or
handling any internal parts of the unit.
Remove the strainer, unscrew the fixing
screws and remove the lower panel
(fig. 1, 2 and 3).
Unscrew and remove drainpan (fig. 4
and 5).
Remove the pre-punched insulation on the
water connection side (fig.6).
Break the blanked drillholes in the water
connection side (fig. 7).
2
Fig. 2 - Abb. 2
Fig. 3 - Abb. 3

Scopo del kit

Lo scopo del kit batteria acqua calda è di
offrire una possibilità di riscaldamento nei
sistemi split di solo raffrescamento
collegandosi ad un'impianto tradizionale di
riscaldamento.
Il kit è compreso anche di termostato
antigelo che protegge la batteria da rotture
dovute alla formazione di ghiaccio
all'interno del circuito.
Il termostato interrompe il funzionamento
del sistema quando la temperatura della
batteria raggiunge +3C° per poi
ripristinarlo a +12C°.
Installazione
IMPORTANTE:
Prima di eseguire qualunque operazione
e di accedere alle parti interne
dell'unità, togliere l'alimentazione
elettrica.
Togliere il filtro aria, svitare le viti di
fissaggio e rimuovere il pannello inferiore
(fig. 1, 2 e 3).
Svitare le viti ed estrarre la bacinella
raccolta condensa (fig. 4 e 5).
Staccare l'isolante pretagliato dalla parte
della connessione dell'acqua (fig. 6).
Rompere i fori pretranciati dalla parte
della connessione acqua (fig. 7).