ELECTRICAL CONNECTION
Check that the power supply corresponds to the label data. QC19 electrical connections must be
accomplished by electricians able to work in respect of the safety rules.
1- GND ground
2- Neutral line 120Vac
3- Phase line 120Vac
4- Motor Common white
5- Motor red
WIND SENSOR
PUSH
BUTTON
1
2
3
4
5
6
QC 19
Remote Control Unit for shutters and awnings.
6 Motor black
7 Wind-sensor
8 Wind-sensor
9 Switch button
10 Switch button
J1
7
8
9
10
Ground
Yellow/Green
Neutral
Blu
Brown
Black
Antenna
Ground
Neutral
Phase
M
Motor
1
2
3
4
5
6
POWER
SUPPLY
230 Vac