2. Receiving the product

2.1 Transporting the product

WARNING
Harm of body
Death or serious personal injury
- Stack maximum two pallets together
under transportation.

3. Installing the product

Installation must be carried out by
specially trained persons and according to
local regulations.
If not already integrated, a water trap (emission trap)
must be fitted in all inlets.
Conlift is not designed for outdoor use.

3.1 Mechanical installation

See also the quick guide supplied with Conlift.
When installing Conlift, observe the following:
The condensate must run freely into the lifting
station.
The cooling slots in the motor cover must not be
covered.
The lifting station should be easily accessible in
order to facilitate maintenance.
The lifting station must be installed in a
well-illuminated and -ventilated room.
The lifting station is protected against splashing
water (in compliance with IP24).
3.1.1 Alarm PCB
The accessory Alarm PCB incorporates a
printed-circuit board (PCB) enabling additional
functions when the level in the tank reaches the
alarm level.
The contact on the PCB can be set to two positions:
Position 1: The pump is started, and an acoustic
alarm is generated.
A: The alarm cable is not connected to the
condensate source or an external alarm. The
condensate source is not switched off.
B: The alarm cable is connected to the condensate
source or an external alarm. The condensate source
is switched off. See section
condensate source or external
Position 2: The pump does not start, and an
acoustic alarm is generated.
A: The alarm cable is not connected to the
condensate source or an external alarm. The
condensate source is not switched off.
B: The alarm cable is connected to the condensate
source or an external alarm. The condensate source
is switched off. See section
condensate source or external
6
3.2.1 Cable to
alarm.
3.2.1 Cable to
alarm.

3.2 Electrical connection

DANGER
Electric shock
Death or serious personal injury
- The protective earth (PE) of the power
outlet must be connected to the
protective earth of the product. The plug
must have the same PE connection
system as the power outlet.
DANGER
Electric shock
Death or serious personal injury
- The installation must be fitted with a
residual current device (RCD) with a
tripping current less than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- The product must be connected to an
external main switch with a minimum
contact gap of 3 mm (0.12 inch) in all
poles.
Electrical connection must be carried out
by an authorized electrician.
Check that the supply voltage and frequency
correspond to the values stated on the nameplate.
The power supply cable has a Schuko plug or a free
cable end. The cable has a length of 2 metres.